27.05.2024 • Product

Detectomat: Sounder-Flasher, Addressable Alarm Device CONUS II – GSA25 Finalist

CONUS II Sounder-Flasher has an integrated battery which allows to install up to 126 alarm devices per loop. The distributed power supply with up to 10 years battery life time for alarm scenarios allows easy design, installation and extension without additional Power Supply Units and without limitations regarding cable type and cable length.

Photo

In most cases there is no need for fire resistant cabling and fire proof housings, which are normally required in Germany. The alarm device is certified for wall and ceiling installation and is available with white and red flash. There are different brightness and volume levels available with up to 95 dB(A). With an integrated detector base additional cabling for detectors could be reduced.

With the integrated battery, up to 126 CONUS II Sounder-Flasher addressable alarm devices could be installed on one loop. Normally the number of alarm devices is much lower, as in most cases the power supply of the Fire Alarm Panel is used. An intelligent battery management informs early about the need of new batteries. At a second step an error occurs, but at this stage the CONUS II is still able to activate the alarm 2 times for 30 minutes. This ensures high reliability about the required alarm duration. Especially for Germany this allows often to ignore the use of fire resistant cabling and fire proof housings. This allows more flexibility during design, installation and extension  as there are no limitations regarding cable length, volume and brightness levels. 

The huge amount of alarm devices per loop also allows more flexibility without adding loops or Fire Alarm Panels which could reduce material cost up to 30% pending on the project type. As the product is certified for wall and ceiling mounting, there are additional advantages for designers and installers, as lots of addressable optical alarm devices are only certified for wall mounting. The white flash is certified for wall mounting with W-2,4-6 and ceiling mounting with C-3-10 according to EN54-23. The red flash is certified for wall mounting with W-2,4-3 and for ceiling mounting with C-3-6.

Business Partner

detectomat GmbH

An der Strusbek 19
22926 Ahrensburg
Germany

Business Partner contact







most read

Photo
12.03.2024 • ProductSafety

DEHNventil ACI M: Standard-compliant Surge Protection in Industry

High demands are placed on the availability of switchgear in, for example, industrial plants, data centres, hospitals and large administrative buildings. This makes surge protection essential. At the same time, replacement of the surge protection module should not influence system availability. The new DEHNventil ACI M TNS 264 FM has no backup fuse and is flexible in terms of its application. In the event of a fault, the protection module is safely disconnected and can be quickly removed from the base part from either side or the front. The touch-safe design allows the protection module to be replaced without system downtime. The ACI technology employed also enables connection cross-sections of just 16 mm2. This facilitates installation and saves time.

Photo
09.04.2024 • ProductSecurity

Cloud Storage Solution for Sensitive Video Material

Review, storage and management of sensitive video clips is now easier with the launch of a new cloud storage solution. Integrated and intelligent security solutions provider 3xLOGIC has introduced VIGIL NVR Case Management, a standalone cloud storage solution for VIGIL NVRs.

Photo
21.03.2024 • ProductSecurity

Stylish New Entrance Control from Gunnebo

Gunnebo Entrance Control has launched SpeedStile FP Glide as a stylish new form of entrance control, designed to meet the evolving security needs of modern offices, public spaces, and commercial buildings.