Dina: Small control system Safeline Vario – GSA25 Finalist

The secure control system Safeline Vario by Dina offers a comprehensive safety solution with up to 30 inputs, monitoring functions like emergency stop, light grids, and safety doors up to Performance Level e or SIL CL 3.

Photo

With free parameterization software and expandability to up to 15 modules, it is ideal for large machines. Measuring only 45/67.5 mm wide, it is compact and versatile, even featuring integrated speed monitoring and comparator function. 

According to Dina, the unique option of evaluating encoder systems with a certified BiSS-Safety interface was recently created. This has also enabled communication with encoders that communicate via BiSS-C. With the safe FSoE bus connection and the integration of all essential safety functions, including sensorless speed monitoring as well as up to 30 inputs and expandability to 15 modules, the Safeline Vario small controller offers a safety solution up to performance level e or SIL CL 3. Its integrated parameterization software enables simple management of safety applications, while its compatibility with various controllers and safety systems offers maximum flexibility. In addition, the Connect communication extension enables a secure connection for remote maintenance and diagnostics as well as the option of subjecting relevant data to automatic fault diagnostics.


Business Partner

Dina Elektronik GmbH

Esslinger Str. 84
72649 Wolfschlugen
Germany

Business Partner contact







most read

Photo
12.03.2024 • ProductSafety

DEHNventil ACI M: Standard-compliant Surge Protection in Industry

High demands are placed on the availability of switchgear in, for example, industrial plants, data centres, hospitals and large administrative buildings. This makes surge protection essential. At the same time, replacement of the surge protection module should not influence system availability. The new DEHNventil ACI M TNS 264 FM has no backup fuse and is flexible in terms of its application. In the event of a fault, the protection module is safely disconnected and can be quickly removed from the base part from either side or the front. The touch-safe design allows the protection module to be replaced without system downtime. The ACI technology employed also enables connection cross-sections of just 16 mm2. This facilitates installation and saves time.

Photo
12.03.2024 • ProductSafety

HVI Light Plus for Lightning Protection Applications

When installing bare, uninsulated air-termination conductors on the roof, the separation distance to electrical and metal systems installed under the roof surface must be maintained in accordance with the current lightning protection standard DIN EN 62305-3. Cable installations, pipe systems or metal parts are frequently installed under the roofing in direct proximity to the air-termination system / down conductor, thus posing a proximity issue. The solution is isolated air-termination systems with high-voltage-resistant, insulated down conductors.